Avoid resetting charge window when charge isn't enabled #549

Merged
merged 2 commits into from
Dec 29, 2023
Merged
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
30 changes: 20 additions & 10 deletions apps/predbat/predbat.py
Original file line number Diff line number Diff line change
Expand Up @@ -18,7 +18,7 @@
import os
import yaml

THIS_VERSION = "v7.14.27"
THIS_VERSION = "v7.14.28"
TIME_FORMAT = "%Y-%m-%dT%H:%M:%S%z"
TIME_FORMAT_SECONDS = "%Y-%m-%dT%H:%M:%S.%f%z"
TIME_FORMAT_OCTOPUS = "%Y-%m-%d %H:%M:%S%z"
Expand Down Expand Up @@ -447,7 +447,7 @@
"options": PREDBAT_MODE_OPTIONS,
"icon": "mdi:state-machine",
"default": PREDBAT_MODE_OPTIONS[PREDBAT_MODE_CONTROL_CHARGEDISCHARGE],
"reset_inverter": True,
"reset_inverter_force": True,
},
{
"name": "update",
Expand Down Expand Up @@ -8677,13 +8677,20 @@ def reset_inverter(self):
if not self.set_read_only or self.inverter_needs_reset_force:
# Don't reset in read only mode unless forced
for inverter in self.inverters:
self.log("Reset inverter settings to safe mode")
inverter.adjust_charge_rate(inverter.battery_rate_max_charge * 60.0 * 1000.0)
inverter.adjust_discharge_rate(inverter.battery_rate_max_discharge * 60 * 1000)
inverter.adjust_force_discharge(False)
inverter.adjust_reserve(0)
inverter.adjust_battery_target(100.0)
inverter.disable_charge_window()
self.log(
"Reset inverter settings to safe mode (set_charge_window={} set_discharge_window={} force={})".format(
self.set_charge_window, self.set_discharge_window, self.inverter_needs_reset_force
)
)
if self.set_charge_window or self.inverter_needs_reset_force:
inverter.adjust_charge_rate(inverter.battery_rate_max_charge * 60.0 * 1000.0)
inverter.disable_charge_window()
inverter.adjust_battery_target(100.0)
if self.set_charge_window or self.set_discharge_window or self.inverter_needs_reset_force:
inverter.adjust_reserve(0)
if self.set_discharge_window or self.inverter_needs_reset_force:
inverter.adjust_discharge_rate(inverter.battery_rate_max_discharge * 60 * 1000)
inverter.adjust_force_discharge(False)
self.inverter_needs_reset = False
self.inverter_needs_reset_force = False

Expand Down Expand Up @@ -9697,24 +9704,27 @@ def fetch_config_options(self):
self.calculate_best_charge = True
self.calculate_best_discharge = False
self.set_charge_window = False
self.set_discharge_window = False
elif self.predbat_mode == PREDBAT_MODE_OPTIONS[PREDBAT_MODE_CONTROL_CHARGE]:
self.calculate_best_charge = True
self.calculate_best_discharge = False
self.set_charge_window = True
self.set_discharge_window = False
elif self.predbat_mode == PREDBAT_MODE_OPTIONS[PREDBAT_MODE_CONTROL_CHARGEDISCHARGE]:
self.calculate_best_charge = True
self.calculate_best_discharge = True
self.set_charge_window = True
self.set_discharge_window = True
else: # PREDBAT_MODE_OPTIONS[PREDBAT_MODE_MONITOR]
self.calculate_best_charge = False
self.calculate_best_discharge = False
self.set_charge_window = False
self.set_discharge_window = False
self.predbat_mode = PREDBAT_MODE_OPTIONS[PREDBAT_MODE_MONITOR]
self.expose_config("mode", self.predbat_mode)

self.log("Predbat mode is set to {}".format(self.predbat_mode))

self.set_discharge_window = self.calculate_best_discharge
self.calculate_discharge_oncharge = self.get_arg("calculate_discharge_oncharge")
self.calculate_second_pass = self.get_arg("calculate_second_pass")
self.calculate_inday_adjustment = self.get_arg("calculate_inday_adjustment")