Add Solax X3-EVC Wallbox #13202

Merged
merged 8 commits into from
Apr 2, 2024
Merged

Add Solax X3-EVC Wallbox #13202

merged 8 commits into from
Apr 2, 2024

Conversation

premultiply
Copy link
Member

@premultiply premultiply commented Mar 29, 2024

NEEDS TESTING

@premultiply premultiply self-assigned this Mar 29, 2024
@premultiply premultiply added devices Specific device support experimental Experimental feature labels Mar 29, 2024 — with GitHub Codespaces
@andig
Copy link
Member

andig commented Mar 29, 2024

Die Erfarhung zeigt, dass sich keine Tester finden- rein damit?

@premultiply
Copy link
Member Author

Lass mal bitte erst noch ein paar Tage stehen.

@Philipp-X1
Copy link

Ich würde testen.
Was muss ich tun?

Hab das ganze übrigens hier auch schon angestoßen: #10750

ist das dann evtl hinfällig?

@premultiply
Copy link
Member Author

Auschecken und übersetzen und dann lokal ausprobieren.

Alternativ kannst du du mal den Modbus-Port auf die Box mal frei geben. -> Slack

@simowNgithub
Copy link

Ich teste auch :) brauche 2-3 Tage.

@Philipp-X1
Copy link

Kenne Slack noch nicht, brauch ich ne Workspace URL?

@nico-schunke
Copy link

Ich teste auch gerne. Jedoch erst ab kommende Woche, da im Urlaub. :-)

@nico-schunke
Copy link

@premultiply

That's how I setup the charger in evcc.yaml

chargers:
  - name: qcells_charger
    type: template
    template: solax
    modbus: tcpip
    id: 70
    host: 192.168.178.120
    port: 502

Thats how the log looks like:

[lp-1  ] ERROR 2024/04/02 12:33:04 charge meter: read tcp 192.168.178.86:49293->192.168.178.120:502: i/o timeout
[site  ] ERROR 2024/04/02 12:33:05 pv 3 power: add[0]: read failed: modbus: exception '2' (illegal data address), function '4'
[site  ] DEBUG 2024/04/02 12:33:05 pv power: 4587W
[site  ] DEBUG 2024/04/02 12:33:05 battery 1 power: -0W
[site  ] DEBUG 2024/04/02 12:33:05 battery 1 soc: 100%
[site  ] DEBUG 2024/04/02 12:33:06 battery 2 power: -0W
[site  ] DEBUG 2024/04/02 12:33:06 battery 2 soc: 100%
[site  ] DEBUG 2024/04/02 12:33:06 battery soc: 100%
[site  ] DEBUG 2024/04/02 12:33:06 battery power: 0W
[site  ] DEBUG 2024/04/02 12:33:06 grid meter: -4190W
[site  ] DEBUG 2024/04/02 12:33:06 site power: -4090W
[lp-1  ] ERROR 2024/04/02 12:33:16 charge meter: read tcp 192.168.178.86:49299->192.168.178.120:502: i/o timeout
[lp-1  ] ERROR 2024/04/02 12:33:26 charge total import: read tcp 192.168.178.86:49303->192.168.178.120:502: i/o timeout
[lp-1  ] DEBUG 2024/04/02 12:33:26 charger status: B
[lp-1  ] DEBUG 2024/04/02 12:33:26 pv charge current: 5.93A = 0A + 5.93A (-4090W @ 3p)
[site  ] DEBUG 2024/04/02 12:33:26 ----
[lp-1  ] ERROR 2024/04/02 12:33:41 charge meter: read tcp 192.168.178.86:49308->192.168.178.120:502: i/o timeout
[site  ] ERROR 2024/04/02 12:33:42 pv 3 power: add[0]: read failed: modbus: exception '2' (illegal data address), function '4'
[site  ] DEBUG 2024/04/02 12:33:42 pv power: 4870W
[site  ] DEBUG 2024/04/02 12:33:42 battery 1 power: -0W
[site  ] DEBUG 2024/04/02 12:33:42 battery 1 soc: 100%
[site  ] DEBUG 2024/04/02 12:33:42 battery 2 power: -0W
[site  ] DEBUG 2024/04/02 12:33:42 battery 2 soc: 100%
[site  ] DEBUG 2024/04/02 12:33:42 battery soc: 100%
[site  ] DEBUG 2024/04/02 12:33:42 battery power: 0W
[site  ] DEBUG 2024/04/02 12:33:42 grid meter: -4481W
[site  ] DEBUG 2024/04/02 12:33:42 site power: -4381W
[lp-1  ] ERROR 2024/04/02 12:33:52 charge meter: read tcp 192.168.178.86:49314->192.168.178.120:502: i/o timeout

Unfortunately, it does not start charing.
I do not have setup a separated meter for the charger.
Forget about the PV 3 power exceptions. I am pretty sure that this is not related to it.

Am I doing anything wrong?

Thanks a lot for your efforts.

@premultiply
Copy link
Member Author

Output of evcc charger --log trace only please.

@nico-schunke
Copy link

nico-schunke commented Apr 2, 2024

Like this?

❯ ./evcc charger --log trace
[main  ] INFO 2024/04/02 12:55:30 evcc 0.124.10 (3d5194e9)
[main  ] INFO 2024/04/02 12:55:30 using config file: /Users/nicoschunke/code/01 PLAYGROUND/evcc-solax-ev-charger/evcc/evcc.yaml
[solax ] TRACE 2024/04/02 12:55:30 modbus: send 00 01 00 00 00 06 46 03 06 28 00 01
[solax ] TRACE 2024/04/02 12:55:30 modbus: recv 00 01 00 00 00 05 46 03 02 02 58
[solax ] TRACE 2024/04/02 12:55:30 modbus: send 00 02 00 00 00 06 46 03 00 0b 00 02
[solax ] TRACE 2024/04/02 12:55:40 modbus: send 00 03 00 00 00 06 46 03 00 10 00 02
[solax ] TRACE 2024/04/02 12:55:50 modbus: send 00 04 00 00 00 06 46 03 00 04 00 06
[solax ] TRACE 2024/04/02 12:56:00 modbus: send 00 05 00 00 00 06 46 03 00 00 00 06
[solax ] TRACE 2024/04/02 12:56:10 modbus: send 00 06 00 00 00 06 46 04 00 1d 00 01
[solax ] TRACE 2024/04/02 12:56:10 modbus: recv 00 06 00 00 00 05 46 04 02 00 02
[solax ] TRACE 2024/04/02 12:56:10 modbus: send 00 07 00 00 00 06 46 03 06 28 00 01
[solax ] TRACE 2024/04/02 12:56:10 modbus: recv 00 07 00 00 00 05 46 03 02 02 58
Power:          read tcp 192.168.178.86:49963->192.168.178.120:502: i/o timeout
Energy:         read tcp 192.168.178.86:49968->192.168.178.120:502: i/o timeout
Current L1..L3: read tcp 192.168.178.86:49971->192.168.178.120:502: i/o timeout
Voltage L1..L3: read tcp 192.168.178.86:49986->192.168.178.120:502: i/o timeout
Charge status:  C
Enabled:        true

@nico-schunke
Copy link

Hat die (/deine) Box eventuell (nur) keine integrierte Energiemessung?

Doch, sollte sie haben. Jedenfalls wird mir der aktuelle Ladestrom immer angezeigt, sofern ich die Q-Cells App benutze (Cloud-Daten, 5 min Latenz). Ich verwende folgendes Modell: https://www.q-cells.de/privatkunden/hardware/wallbox
In Kombination mit dem Q-Cells WR, funktioniert auch das Überschussladen (direkte Kommunikation WB zu WR erforderlich).

Unter der 192.168.178.120 liegt ein Modbus TVP RTU (Waveshare), an welchem nur die WB angeklemmt ist.

@Philipp-X1
Copy link

Ist damit die tatsächliche Ladeleistung gemeint?
Das sollte für
L1 register = 0x8
L2 register = 0x9
L3 register = 0xA

und register "Charge Power Total" = 0xB

zumindest hab ich dafür saubere Werte in HomeAssistant.

Es gibt nämlich einige Register die Grid Load werte anzeigen aber das nie tun werden da diese Werte eigentlich von den Klappenwandlern kommen welche aber nicht genutzt werden können sobald man die Box über Modbus verbindet. ( Zumidest habe ich es noch nicht probiert, dürfte aber nicht gehen

@nico-schunke
Copy link

nico-schunke commented Apr 2, 2024

Ist damit die tatsächliche Ladeleistung gemeint? Das sollte für L1 register = 0x8 L2 register = 0x9 L3 register = 0xA

und register "Charge Power Total" = 0xB

zumindest hab ich dafür saubere Werte in HomeAssistant.

Es gibt nämlich einige Register die Grid Load werte anzeigen aber das nie tun werden da diese Werte eigentlich von den Klappenwandlern kommen welche aber nicht genutzt werden können sobald man die Box über Modbus verbindet. ( Zumidest habe ich es noch nicht probiert, dürfte aber nicht gehen

Das würde ich so bestätigen (lade gerade 3-phasig mit 6A):

image

@premultiply
Copy link
Member Author

Bitte jetzt nochmal. Hatte die Anpassung der Funktionen vergessen.

@nico-schunke
Copy link

❯ ./evcc charger --log trace
[main  ] INFO 2024/04/02 13:44:30 evcc 0.124.10 (7f4797bb)
[main  ] INFO 2024/04/02 13:44:30 using config file: /Users/nicoschunke/code/01 PLAYGROUND/evcc-solax-ev-charger/evcc/evcc.yaml
[solax ] TRACE 2024/04/02 13:44:30 modbus: send 00 01 00 00 00 06 46 03 06 28 00 01
[solax ] TRACE 2024/04/02 13:44:30 modbus: recv 00 01 00 00 00 05 46 03 02 06 40
[solax ] TRACE 2024/04/02 13:44:30 modbus: send 00 02 00 00 00 06 46 04 00 0b 00 02
[solax ] TRACE 2024/04/02 13:44:31 modbus: recv 00 02 00 00 00 07 46 04 04 10 8a 13 8e
[solax ] TRACE 2024/04/02 13:44:31 modbus: send 00 03 00 00 00 06 46 04 00 10 00 02
[solax ] TRACE 2024/04/02 13:44:31 modbus: recv 00 03 00 00 00 07 46 04 04 00 00 20 f4
[solax ] TRACE 2024/04/02 13:44:31 modbus: send 00 04 00 00 00 06 46 04 00 04 00 06
[solax ] TRACE 2024/04/02 13:44:31 modbus: recv 00 04 00 00 00 0f 46 04 0c 02 55 02 64 02 64 00 03 05 68 05 91
[solax ] TRACE 2024/04/02 13:44:31 modbus: send 00 05 00 00 00 06 46 04 00 00 00 06
[solax ] TRACE 2024/04/02 13:44:31 modbus: recv 00 05 00 00 00 0f 46 04 0c 5a c9 5b 02 5a fb 00 0e 02 55 02 64
[solax ] TRACE 2024/04/02 13:44:31 modbus: send 00 06 00 00 00 06 46 04 00 1d 00 01
[solax ] TRACE 2024/04/02 13:44:31 modbus: recv 00 06 00 00 00 05 46 04 02 00 02
[solax ] TRACE 2024/04/02 13:44:31 modbus: send 00 07 00 00 00 06 46 03 06 28 00 01
[solax ] TRACE 2024/04/02 13:44:31 modbus: recv 00 07 00 00 00 05 46 03 02 06 40
Power:          277484W
Energy:         843.6kWh
Current L1..L3: 3.91e+05A 4.01e+05A 9.07e+05A
Voltage L1..L3: 1.52e+07V 1.53e+07V 3.91e+05V
Charge status:  C
Enabled:        true

@premultiply
Copy link
Member Author

Ok, die Decodierung und Skalierung stimmt noch nicht ganz aber zumindest kann jetzt schon mal alles gelesen werden. 👍🏼

@premultiply
Copy link
Member Author

Probier nochmal bitte.

@nico-schunke
Copy link

Das sieht deutlich besser aus. Habe nur gerade kein Auto vor der Tür, mit welchem ich testen könnte.

❯ ./evcc charger --log trace
[main  ] INFO 2024/04/02 17:13:21 evcc 0.124.10 (affb5c9a)
[main  ] INFO 2024/04/02 17:13:21 using config file: /Users/nicoschunke/code/01 PLAYGROUND/evcc-solax-ev-charger/evcc/evcc.yaml
[solax ] TRACE 2024/04/02 17:13:21 modbus: send 00 01 00 00 00 06 46 03 06 28 00 01
[solax ] TRACE 2024/04/02 17:13:21 modbus: recv 00 01 00 00 00 05 46 03 02 00 00
[solax ] TRACE 2024/04/02 17:13:21 modbus: send 00 02 00 00 00 06 46 04 00 0b 00 01
[solax ] TRACE 2024/04/02 17:13:21 modbus: recv 00 02 00 00 00 05 46 04 02 00 07
[solax ] TRACE 2024/04/02 17:13:21 modbus: send 00 03 00 00 00 06 46 04 00 10 00 02
[solax ] TRACE 2024/04/02 17:13:22 modbus: recv 00 03 00 00 00 07 46 04 04 00 00 21 26
[solax ] TRACE 2024/04/02 17:13:22 modbus: send 00 04 00 00 00 06 46 04 00 04 00 03
[solax ] TRACE 2024/04/02 17:13:22 modbus: recv 00 04 00 00 00 09 46 04 06 00 00 00 00 00 00
[solax ] TRACE 2024/04/02 17:13:22 modbus: send 00 05 00 00 00 06 46 04 00 00 00 03
[solax ] TRACE 2024/04/02 17:13:22 modbus: recv 00 05 00 00 00 09 46 04 06 5d 3e 5d 7b 5d 81
[solax ] TRACE 2024/04/02 17:13:22 modbus: send 00 06 00 00 00 06 46 04 00 1d 00 01
[solax ] TRACE 2024/04/02 17:13:22 modbus: recv 00 06 00 00 00 05 46 04 02 00 00
[solax ] TRACE 2024/04/02 17:13:22 modbus: send 00 07 00 00 00 06 46 03 06 28 00 01
[solax ] TRACE 2024/04/02 17:13:22 modbus: recv 00 07 00 00 00 05 46 03 02 00 00
Power:          7W
Energy:         848.6kWh
Current L1..L3: 0A 0A 0A
Voltage L1..L3: 239V 239V 239V
Charge status:  A
Enabled:        false

@premultiply
Copy link
Member Author

Jetzt ist noch interessant ob auch die Ladefreigabe, Stromanpassung und Phasenumschaltung wie erwartet funktioniert:

evcc help charger
Query configured chargers

Usage:
  evcc charger [name] [flags]
  evcc charger [command]

Available Commands:
  ramp        Ramp current from 6..16A in configurable steps

Flags:
  -i, --current int   Set maximum current
      --diagnose      Diagnose
  -d, --disable       Disable
  -e, --enable        Enable
  -p, --phases int    Set usable phases (1 or 3)
  -w, --wakeup        Wake up

Global Flags:
  -c, --config string   Config file (default "~/evcc.yaml" or "/etc/evcc.yaml")
  -h, --help            Help
  -l, --log string      Log level (fatal, error, warn, info, debug, trace) (default "info")
      --log-headers     Log headers

Use "evcc charger [command] --help" for more information about a command.

@Philipp-X1
Copy link

Phasenumschaltung gibt es wahrscheinlich gar nicht.
Ist glaub auch nicht in der Produktspezifikation von Solax erwähnt. Hab die Info aus dem Photovoltaikforum von einem User das wohl gerade eine neue Wallbox mit Phasenumschaltung entwickelt wird.
Warum es dafür Modbusregister gibt? Keine Ahnung, evtl. schon vorbereitet. ¯_(ツ)_/¯ Lasse mich gerne eines besseren belehren.

Ansonsten würde ich auch gern testen, bin aber unfähig die nötigen änderung im HomeAssistant Addon durchzuführen…

@lieglw
Copy link

lieglw commented May 27, 2024

Hi, we also have a Mini SE and a 330e. As far as I know the Mini does not charge with single phase, but the 330e only has this possibility. Have 2 Solax EV Chargers 11kW
image

But can also test with the Mini

@hnehnes
Copy link

hnehnes commented May 27, 2024

Da ich den Mini auch an der normalen Steckdose mit dem BMW Battery Charger laden kann, gehe ich davon aus, dass der Mini auch einphasig laden kann.

@lieglw
Copy link

lieglw commented May 27, 2024

Sorry my fault. @hnehnes you are right the mini can charge single phase.
Have also tried and it seems it is not a set parameter.

@GrimmiMeloni
Copy link
Collaborator

GrimmiMeloni commented May 28, 2024

Ich habe gestern Abend nochmal direkten Zugriff auf einen (3-phasigen) SolaX X3 EVC 22K gehabt. Dieser hat kein Waveshare Adapter, daher war "nur" die HTTP API benutzbar. Trotzdem bin ich mir relativ sicher gestern live gesehen zu haben daß die Box definitiv keinen Phase Switch unterstützt. Der fragliche Modbus register 0x0625 kann zwar geschrieben werden (geht auch über die HTTP API), und die Box quittitert das auch Positiv, nur hat dies überhaupt keine Auswirkung.

@premultiply ich würde vorschlagen den Phase Switch Support in der Doku nicht mehr zu erwähnen. Des weiteren halte ich es für sinnvoll auch die Implementierung des Phase Switchers zu entfernen. Für 3-phasige Boxen ist es ein No-Op. Für 1-phasige passiert vermutlich "dummes Zeug". So wie ich die Doku verstehe definiert der Register die Konfiguration der Box auf welcher Phase (L1 - L3) diese angeschlossen ist. Es macht daher keinen Sinn das wir diesen Register schreiben.

@premultiply
Copy link
Member Author

#14108

@Philipp-X1
Copy link

Habe jetzt schon mehrfach gehört das die Wallbox nach dem Firmwareupdate tot ist…
Würde erstmal kein Firmwareupdate mehr empfehlen bis die das im Griff haben…

@hnehnes
Copy link

hnehnes commented Jun 5, 2024

Das scheint zu stimmen. Meine ist auch tot und Solax hat keine mehr auf Lager. Daher hat man dann erstmal keine Wallbox mehr...

@nico-schunke
Copy link

jfyi: Exakt dies ist bei mir auch passiert. Im Zuge des Testens hier und der Erkenntnis, dass mit meiner alten Firmware die Integration nicht möglich ist, habe ich das Firmware Update veranlasst. Seit dem Versuch des Aufspielens war der Charger tot. Ich haben dann zusammen mit dem Support viele Dinge probiert, bis hin zum manuellen flashen am USB-Port am Charger selbst (btw: habe die Firmware v1.13 vorliegen - falls jemand Interesse hat, bitte melden). Alles ohne Erfolg.
Ergebnis: der Charger ging nun zurück. Wollte kein Austauschgerät, sondern eine Alternative. Ich habe mich für den Warp3 von Tinkerforge entschieden, was ich bisher keine Sekunde bereut habe. Geiles Teil, hervorragend Features, sehr gute APIs und Dokumentation und ein robustes modulares System. Ganz klare Empfehlung (im Vergleich zu QCells).

@hnehnes
Copy link

hnehnes commented Jun 6, 2024

Das mit USB etc. habe ich auch probiert und da die Steuerung der Box ja vermutlich auf einem ESP32 basiert, sollte ein flashen auch möglich sein, wenn die geflashte Firmware nicht funktioniert. Ich kann die Box leider nicht zurück schicken, da ich sie von QCells zusammen mit der Solaranlage erworben habe. Und da der QCells Support quasi keiner ist, kann das jetzt dauern. Solax selbst hat aktuell keine Boxen auf Lager.

@nico-schunke
Copy link

Habe die Box ebenfalls im Zusammenhang mit der PV erworben. Mein Solateur hat einen Support-Case bei QCells eröffnet und der Austausch erfolgte recht fix und unverzüglich (glaube nach 3-4 Werktagen war die neue da).

@hnehnes
Copy link

hnehnes commented Jun 6, 2024

Ich habe die direkt bei QCells beauftragt, daher habe ich keinen Solateur dazwischen...

@Philipp-X1
Copy link

Philipp-X1 commented Jun 6, 2024

Gibt’s denn jemanden der die Solax Wallbox hat und auch das Update Problem? Klingt so als wären es hauptsächlich QCells Boxen? ( obwohl wir ja eigentlich davon ausgehen das die Baugleich sind )

Oder anders, gibts überhaupt jemanden bei dem das Update funktioniert hat?

@simowNgithub
Copy link

simowNgithub commented Jun 6, 2024

Gibt’s denn jemanden der die Solax Wallbox hat und auch das Update Problem? Klingt so als wären es hauptsächlich QCells Boxen? ( obwohl wir ja eigentlich davon ausgehen das die Baugleich sind )

Oder anders, gibts überhaupt jemanden bei dem das Update funktioniert hat?

ich habe eine solax box und das gleiche problem und angeblich ist die austauschbox unterwegs.

EDIT: Box kam mit neuer Gen 1.1 eine Woche später an.

@hnehnes
Copy link

hnehnes commented Jun 20, 2024

Hab jetzt eine neue Box, scheinbar mit Version 1.12. da geht da funktioniert EVCC, aber das Starten muss man manuell an der Box machen. Leider ist das WLAN der neuen Box so schlecht, dass das Signal nach 2 Metern abreisst. Daher kann ich sie nicht per HTTP starten.

@Philipp-X1
Copy link

Hast du die Wallbox in der Solax App auf Fast gestellt?

@hnehnes
Copy link

hnehnes commented Jun 20, 2024

Jup hab ich gemacht. Das Regeln der Watt funktioniert, aber der Start nicht. Aber das liegt vermutlich daran, dass die Version 1.12 und nicht 1.13 ist.

@Philipp-X1
Copy link

Das Ding ist, im Photovoltaik Forum hat einer geschrieben das es mit 1.12 läuft…

Man müsste wohl mal bei 1.12 das control command Modbus Register durchtesten… Weiß ja nicht welche Möglichkeiten du so hast.
Ansonsten müsste man wohl mal den Support fragen ob sie den Fehler bei 1.13 schon behoben haben….

@hnehnes
Copy link

hnehnes commented Jun 21, 2024

Ich warte gerade auf den Support, da bei der Box das WLAN nicht richtig funktioniert. Daher kommt vermutlich nochmal eine neue Box...

@hnehnes
Copy link

hnehnes commented Jun 26, 2024

Das Ding ist, im Photovoltaik Forum hat einer geschrieben das es mit 1.12 läuft…

Man müsste wohl mal bei 1.12 das control command Modbus Register durchtesten… Weiß ja nicht welche Möglichkeiten du so hast. Ansonsten müsste man wohl mal den Support fragen ob sie den Fehler bei 1.13 schon behoben haben….

Also es ist definitiv 1.12 und das automatische Anstarten funktioniert nicht. Wenn die Ladung stoppt muss ich manuell wieder die Wallbox auf Fast stellen damit es weitergeht. Wie kann ich die Modbus Register durchtesten?

@Philipp-X1
Copy link

Entweder mit einem Modbus Tool ( kenne mich da leider nicht aus ) Oder falls du HomeAssistant hast gäbe es dafür eine Integration. Bei der ist aber der Control Command noch auskommentiert. Das kann man aber von Hand im Code ändern.
Damit kannst du dann alles was die Box so kann steuern.

Aber wenn du es so sagst dann geht es wohl wirklich erst ab 1.13…

@hnehnes
Copy link

hnehnes commented Jun 26, 2024

ich habe das alles in HA, auch EVCC. Welche Integration meinst du?

@Philipp-X1
Copy link

Ich meine diese Integration:

https://github.com/wills106/homeassistant-solax-modbus

Hier kann man beim aufsetzen unter Wechselrichtertyp Solax EV Charger auswählen. Damit wird dann die Integration passend für die Wallbox eingerichtet.
Das ist dann die Modbus Integration für HA.

Ich hab die dauerhaft über einen Modbusproxy am laufen. Wenn du nur mal testen willst ist es denk ich ok. Wenn du es dauerhaft neben EVCC laufen lassen willst ist es sinnvoll einen Proxy einzurichten weil zwei Anwendungen auf ein Modbusgerät zugreifen.

@hnehnes
Copy link

hnehnes commented Jul 2, 2024

Die Integration nutze ich auch für meinen Wechselrichter. Ich kann damit auch auf die Wallbox zugreifen. Ich probiere jetzt nochmal, ob ich damit das Laden starten kann.

@Philipp-X1
Copy link

Genau, ist die selbe.

wie gesagt man muss noch mit einem Editor bei den Code Zeilen vom Control Command das auskommentieren weg nehmen.

Diese hier:

IMG_4097
IMG_4096

( das erscheint da zweimal muss bei beiden gemacht werden )

erst dann hast du den Control Command in HA

@hnehnes
Copy link

hnehnes commented Jul 2, 2024

erledigt. Sobald ich Zeit habe werde ich es testen.

Nur damit wir übers gleiche reden: Ich stoppe über HA das Laden und starte es dann über HA wieder an.

@Philipp-X1
Copy link

Richtig.
Sobald du den Control Command auf Start charging stellst sollte die Wallbox in den letzten Modi zurückspringen in dem sie vor dem letzten Stop war ( Green, Eco oder Fast ) und mit dem Laden beginnen.

@hnehnes
Copy link

hnehnes commented Jul 2, 2024

Also gerade ausprobiert.
Auto mit Wallbox verbunden. Wallbox springt auf Fast und lädt mit 11 KW
Über Homeassistant Control Command Stop Charging - Wallbox Stoppt.
Über Homeassistant Control Command Start Charging - Wallbox Startet wieder.

Über EVCC hatte ich das Verhalten, dass die Wallbox mit dem Laden startet sobald das Kabel eingesteckt wird. Wenn zu wenig Sonne für Überschussladen vorhanden ist, kann EVCC das Laden stoppen, bei genügend Sonne startet das Laden aber nicht. Kann es sein, dass in EVCC das falsche Register genutzt wird?

@premultiply
Copy link
Member Author

Ich würde euch bitten die weiteren persönlichen Versuche gerne in eine Diskussion auszulagern,
da dass mit dem Issue und der Integration in evcc nichts hier mehr zu tun hat.

Wenn es tatsächlich von uns lösbare Probleme geben sollte gerne ein neues, qualifiziertes Issue dazu.

Ich mache hier jetzt mal zu.