Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathSunSynk8.8-ESPHome.yaml
1626 lines (1471 loc) · 49.2 KB
/
SunSynk8.8-ESPHome.yaml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
# Substitutions
substitutions:
# Device Names
device_name: "sunsynk"
friendly_name: "SunSynk"
device_description: "Sunsynk RS485 Logger"
settings_skipped_updates: "4"
# Icon
main_icon: "solar-power"
# Basic Config
esphome:
name: "${device_name}"
comment: '${device_description}'
esp32:
board: lolin32_lite
framework:
type: arduino
# Enable logging
logger:
baud_rate: 0
# Enable Home Assistant API
api:
encryption:
key: !secret api_encryption_key
# OTA Updates Password
ota:
platform: esphome
password: !secret sunsynk_ota_password
# Enable Webserver
web_server:
port: 80
auth:
username: !secret web_server_username
password: !secret web_server_password
ota: true
# Wifi Setup
wifi:
ssid: !secret Wifi_SSID
password: !secret Wifi_Password
# Enable fallback hotspot (captive portal) in case wifi connection fails
ap:
ssid: "${device_name} Hotspot"
password: !secret Fallback_Wifi_Password
fast_connect: true
power_save_mode: none
# Enable captive portal on fallback wifi
captive_portal:
# Enable time component to reset energy at midnight
# https://esphome.io/components/time.html#home-assistant-time-source
time:
- platform: homeassistant
id: homeassistant_time
uart:
id: mod_bus
tx_pin: GPIO16
rx_pin: GPIO17
baud_rate: 9600
stop_bits: 1
modbus:
id: sunsynk_modbus
modbus_controller:
- id: sunsynk
address: 0x01
modbus_id: sunsynk_modbus
setup_priority: -10
update_interval: "5s"
command_throttle: "50ms"
############################################### BINARY SENSORS ###############################################
binary_sensor:
- platform: modbus_controller # 194 Grid Connected Status
modbus_controller_id: sunsynk
name: "${friendly_name} Grid Connected Status"
id: sunsynk_grid_connected_status
register_type: holding
address: 194
- platform: modbus_controller # 280 Grid Peak Shaving Status
modbus_controller_id: sunsynk
name: "${friendly_name} Grid Peak Shaving Status"
id: sunsynk_grid_peak_shaving_status
register_type: holding
address: 280
bitmask: 0x100
############################################### SENSORS ###############################################
sensor:
##########
# General
##########
- platform: wifi_signal # WiFi Signal Sensor
name: "${friendly_name} WiFi Status"
update_interval: 60s
entity_category: diagnostic
- platform: modbus_controller # 090 DC Transformer Temperature
modbus_controller_id: sunsynk
name: "${friendly_name} DC Transformer Temperature"
id: sunsynk_dctransformer_temperature
register_type: holding
address: 090
unit_of_measurement: "°C"
accuracy_decimals: 1
device_class: temperature
state_class: measurement
value_type: S_WORD
filters:
- offset: -1000
- multiply: 0.1
- platform: modbus_controller # 091 DC Heatsink Temperature
modbus_controller_id: sunsynk
name: "${friendly_name} DC Heatsink Temperature"
id: sunsynk_heatsink_temperature
register_type: holding
address: 091
unit_of_measurement: "°C"
accuracy_decimals: 1
device_class: temperature
state_class: measurement
value_type: S_WORD
filters:
- offset: -1000
- multiply: 0.1
##########
# Battery
##########
- platform: modbus_controller # 182 Battery Temperature
modbus_controller_id: sunsynk
name: "${friendly_name} Battery Temperature"
id: sunsynk_battery_temperature
register_type: holding
address: 182
unit_of_measurement: "°C"
accuracy_decimals: 1
device_class: temperature
state_class: measurement
value_type: U_WORD
filters:
- offset: -1000
- multiply: 0.1
- platform: modbus_controller # 183 Battery Voltage
modbus_controller_id: sunsynk
name: "${friendly_name} Battery Voltage"
id: sunsynk_battery_voltage
register_type: holding
address: 183
unit_of_measurement: "V"
accuracy_decimals: 1
device_class: voltage
state_class: measurement
filters:
- multiply: 0.01
value_type: U_WORD
- platform: modbus_controller # 184 Battery SOC
modbus_controller_id: sunsynk
name: "${friendly_name} Battery SOC"
id: sunsynk_battery_soc
register_type: holding
address: 184
unit_of_measurement: "%"
accuracy_decimals: 0
device_class: battery
state_class: measurement
value_type: U_WORD
- platform: modbus_controller # 190 Battery Output Power
modbus_controller_id: sunsynk
name: "${friendly_name} Battery Output Power"
id: sunsynk_battery_output_power
register_type: holding
address: 190
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
value_type: S_WORD
- platform: modbus_controller # 191 Battery Output Current
modbus_controller_id: sunsynk
name: "${friendly_name} Battery Output Current"
id: sunsynk_battery_output_current
register_type: holding
address: 191
unit_of_measurement: "A"
accuracy_decimals: 1
device_class: current
state_class: measurement
value_type: S_WORD
filters:
- multiply: 0.01
- platform: modbus_controller # 314 Battery Charge Limit current
modbus_controller_id: sunsynk
name: "${friendly_name} Battery Charge Limit current"
id: sunsynk_battery_charge_limit_current
register_type: holding
address: 314
unit_of_measurement: "A"
accuracy_decimals: 0
device_class: current
state_class: measurement
value_type: S_WORD
- platform: modbus_controller # 315 Battery Discharge Limit current
modbus_controller_id: sunsynk
name: "${friendly_name} Battery Discharge Limit current"
id: sunsynk_battery_discharge_limit_current
register_type: holding
address: 315
unit_of_measurement: "A"
accuracy_decimals: 0
device_class: current
state_class: measurement
value_type: S_WORD
- platform: modbus_controller # 217 Battery Capacity Shutdown
modbus_controller_id: sunsynk
name: "${friendly_name} Battery Capacity Shutdown"
id: sunsynk_battery_capacity_shutdown
register_type: holding
address: 217
unit_of_measurement: "%"
accuracy_decimals: 0
device_class: battery
state_class: measurement
###########
# Battery Pack 1
###########
# - platform: modbus_controller # 10047 Battery Pack1 SOC
# modbus_controller_id: sunsynk
# name: "${friendly_name} Battery Pack1 SOC"
# id: sunsynk_battery_pack1_soc
# register_type: holding
# address: 10047
# unit_of_measurement: "%"
# accuracy_decimals: 0
# device_class: battery
# state_class: measurement
# value_type: U_WORD
###########
# Inverter
###########
- platform: modbus_controller # 175 Inverter Output Power
modbus_controller_id: sunsynk
name: "${friendly_name} Inverter Output Power"
id: sunsynk_inverter_output_power
register_type: holding
address: 175
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
value_type: S_WORD
- platform: modbus_controller # 154 Inverter Voltage
modbus_controller_id: sunsynk
name: "${friendly_name} Inverter Voltage"
id: sunsynk_inverter_voltage
register_type: holding
address: 154
unit_of_measurement: "V"
accuracy_decimals: 1
device_class: voltage
state_class: measurement
value_type: U_WORD
filters:
- multiply: 0.1
- platform: modbus_controller # 164 Inverter Output Current
modbus_controller_id: sunsynk
name: "${friendly_name} Inverter Output Current"
id: sunsynk_inverter_output_current
register_type: holding
address: 164
unit_of_measurement: "A"
accuracy_decimals: 1
device_class: current
state_class: measurement
value_type: S_WORD
filters:
- multiply: 0.01
- platform: modbus_controller # 193 Grid Frequency
modbus_controller_id: sunsynk
name: "${friendly_name} Inverter Frequency"
id: sunsynk_inverter_frequency
register_type: holding
address: 193
unit_of_measurement: "Hz"
accuracy_decimals: 2
state_class: measurement
value_type: U_WORD
filters:
- multiply: 0.01
#######
# Grid
#######
- platform: modbus_controller # 079 Grid Frequency
modbus_controller_id: sunsynk
name: "${friendly_name} Grid Frequency"
id: sunsynk_grid_frequency
register_type: holding
address: 79
unit_of_measurement: "Hz"
accuracy_decimals: 2
state_class: measurement
value_type: U_WORD
filters:
- multiply: 0.01
- platform: modbus_controller # 169 Grid Power = L1(167) + L2(168)
modbus_controller_id: sunsynk
name: "${friendly_name} Grid Power"
id: sunsynk_grid_power
register_type: holding
address: 169
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
value_type: S_WORD
- platform: modbus_controller # 167 Grid LD Power = L1 seems to be LD
modbus_controller_id: sunsynk
name: "${friendly_name} Grid LD Power"
id: sunsynk_grid_ld_power
register_type: holding
address: 167
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
value_type: S_WORD
- platform: modbus_controller # 168 Grid L2 Power
modbus_controller_id: sunsynk
name: "${friendly_name} Grid L2 Power"
id: sunsynk_grid_l2_power
register_type: holding
address: 168
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
value_type: S_WORD
- platform: modbus_controller # 150 Grid Voltage
modbus_controller_id: sunsynk
name: "${friendly_name} Grid Voltage"
id: sunsynk_grid_voltage
register_type: holding
address: 150
unit_of_measurement: "V"
accuracy_decimals: 1
device_class: voltage
state_class: measurement
value_type: U_WORD
filters:
- multiply: 0.1
- platform: modbus_controller #160 and 161 Grid Current signed 32 bit integer from 2 registers low word first
modbus_controller_id: sunsynk
name: "${friendly_name} Grid Current"
id: sunsynk_grid_current
register_type: holding
address: 160
unit_of_measurement: "A"
accuracy_decimals: 1
device_class: current
state_class: measurement
value_type: U_DWORD_R
filters:
- multiply: 0.01
- platform: modbus_controller # 172 Grid CT Power
modbus_controller_id: sunsynk
name: "${friendly_name} Grid CT Power"
id: sunsynk_grid_ct_power
register_type: holding
address: 172
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
value_type: S_WORD
#######
# Load
#######
- platform: modbus_controller # 178 Load Power = L1(176) + L2(177)
modbus_controller_id: sunsynk
name: "${friendly_name} Load Power"
id: sunsynk_load_power
register_type: holding
address: 178
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
value_type: S_WORD
- platform: modbus_controller # 176 Load L1 Power
modbus_controller_id: sunsynk
name: "${friendly_name} Load L1 Power"
id: sunsynk_load_l1_power
register_type: holding
address: 176
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
value_type: S_WORD
- platform: modbus_controller # 177 Load L2 Power
modbus_controller_id: sunsynk
name: "${friendly_name} Load L2 Power"
id: sunsynk_load_l2_power
register_type: holding
address: 177
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
value_type: S_WORD
- platform: modbus_controller # 192 Load Frequency
modbus_controller_id: sunsynk
name: "${friendly_name} Load Frequency"
id: sunsynk_load_frequency
register_type: holding
address: 192
unit_of_measurement: "Hz"
accuracy_decimals: 2
state_class: measurement
value_type: U_WORD
filters:
- multiply: 0.01
#############
# Solar PV
#############
- platform: modbus_controller # 186 PV1 Power
modbus_controller_id: sunsynk
name: "${friendly_name} PV1 Power"
id: sunsynk_pv1_power
register_type: holding
address: 186
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
value_type: U_WORD
- platform: modbus_controller # 109 PV1 Voltage
modbus_controller_id: sunsynk
name: "${friendly_name} PV1 Voltage"
id: sunsynk_pv1_voltage
register_type: holding
address: 109
unit_of_measurement: "V"
device_class: voltage
state_class: measurement
value_type: U_WORD
filters:
- multiply: 0.1
- platform: modbus_controller # 110 PV1 Output Current
modbus_controller_id: sunsynk
name: "${friendly_name} PV1 Current"
id: sunsynk_pv1_current
register_type: holding
address: 110
unit_of_measurement: "A"
accuracy_decimals: 1
device_class: current
state_class: measurement
value_type: U_WORD
filters:
- multiply: 0.1
- platform: modbus_controller # 187 PV2 Power
modbus_controller_id: sunsynk
name: "${friendly_name} PV2 Power"
id: sunsynk_pv2_power
register_type: holding
address: 187
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
value_type: U_WORD
- platform: modbus_controller # 111 PV2 Voltage
modbus_controller_id: sunsynk
name: "${friendly_name} PV2 Voltage"
id: sunsynk_pv2_voltage
register_type: holding
address: 111
unit_of_measurement: "V"
device_class: voltage
state_class: measurement
value_type: U_WORD
filters:
- multiply: 0.1
- platform: modbus_controller # 112 PV2 Output Current
modbus_controller_id: sunsynk
name: "${friendly_name} PV2 Current"
id: sunsynk_pv2_current
register_type: holding
address: 112
unit_of_measurement: "A"
accuracy_decimals: 1
device_class: current
state_class: measurement
value_type: U_WORD
filters:
- multiply: 0.1
- platform: template # Sum of PV1 and PV2 to get total PV Power
name: "${friendly_name} Total Solar"
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
lambda: |-
return (id(sunsynk_pv1_power).state + id(sunsynk_pv2_power).state);
update_interval: 2s
###################
# Power on Outputs
###################
- platform: modbus_controller # 166 Aux Output Power
modbus_controller_id: sunsynk
name: "${friendly_name} Aux Output Power"
id: sunsynk_aux_output_power
register_type: holding
address: 166
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
value_type: S_WORD
- platform: template # Essential Power based on register 175 + 169 - 166
name: "${friendly_name} Essential Power"
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
lambda: |-
return (id(sunsynk_inverter_output_power).state + id(sunsynk_grid_power).state - id(sunsynk_aux_output_power).state);
update_interval: 2s
- platform: template # UPS Power (Essential 1 Power) based on register 175 + 167 - 166
name: "${friendly_name} UPS Power"
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
lambda: |-
return (id(sunsynk_inverter_output_power).state + id(sunsynk_grid_ld_power).state - id(sunsynk_aux_output_power).state);
update_interval: 2s
- platform: template # Essential 2 Power based on register 175 + 169 - 166
name: "${friendly_name} Essential 2 Power"
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
lambda: |-
return (id(sunsynk_inverter_output_power).state + id(sunsynk_grid_power).state - id(sunsynk_aux_output_power).state);
update_interval: 2s
- platform: template # Nonessential Power(House Load) 172 - 167
name: "${friendly_name} House Power"
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
lambda: |-
return (id(sunsynk_grid_ct_power).state - id(sunsynk_grid_ld_power).state);
update_interval: 2s
- platform: template # Nonessential Power 175 - 167
name: "${friendly_name} Non-Essential Power"
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
lambda: |-
return (id(sunsynk_inverter_output_power).state - id(sunsynk_grid_ld_power).state);
update_interval: 2s
#########
# Energy
#########
- platform: modbus_controller # 070 Daily Battery Charge
modbus_controller_id: sunsynk
name: "${friendly_name} Daily Battery Charge"
id: sunsynk_battery_charge_day
register_type: holding
address: 70
unit_of_measurement: "kWh"
accuracy_decimals: 2
device_class: energy
state_class: total_increasing
value_type: U_WORD
filters:
- multiply: 0.1
- platform: modbus_controller # 071 Daily Battery Discharge
modbus_controller_id: sunsynk
name: "${friendly_name} Daily Battery Discharge"
id: sunsynk_battery_discharge_day
register_type: holding
address: 71
unit_of_measurement: "kWh"
accuracy_decimals: 2
device_class: energy
state_class: total_increasing
value_type: U_WORD
filters:
- multiply: 0.1
- platform: modbus_controller # 076 Daily Grid Import
modbus_controller_id: sunsynk
name: "${friendly_name} Daily Grid Import"
id: sunsynk_grid_import_day
register_type: holding
address: 76
unit_of_measurement: "kWh"
accuracy_decimals: 2
device_class: energy
state_class: total_increasing
value_type: U_WORD
filters:
- multiply: 0.1
- platform: modbus_controller # 077 Daily Grid Export
modbus_controller_id: sunsynk
name: "${friendly_name} Daily Grid Export"
id: sunsynk_grid_export_day
register_type: holding
address: 77
unit_of_measurement: "kWh"
accuracy_decimals: 2
device_class: energy
state_class: total_increasing
value_type: U_WORD
filters:
- multiply: 0.1
- platform: modbus_controller # 084 Daily Load
modbus_controller_id: sunsynk
name: "${friendly_name} Daily Load Power (kWh)"
id: sunsynk_daily_load_power_kwh
register_type: holding
address: 84
unit_of_measurement: "kWh"
accuracy_decimals: 2
device_class: energy
state_class: total_increasing
value_type: U_WORD
filters:
- multiply: 0.1
- platform: modbus_controller # 108 Daily PV Power
modbus_controller_id: sunsynk
name: "${friendly_name} Daily PV Power (kWh)"
id: sunsynk_daily_pv_power_kwh
register_type: holding
address: 108
unit_of_measurement: "kWh"
accuracy_decimals: 2
device_class: energy
state_class: total_increasing
value_type: U_WORD
filters:
- multiply: 0.1
- platform: modbus_controller #72 and 73 Total Battery Charge unsigned 32 bit integer from 2 registers low word first
modbus_controller_id: sunsynk
name: "${friendly_name} Total Battery Charge (kWh)"
id: sunsynk_total_battery_charge_kwh
register_type: holding
address: 72
unit_of_measurement: "kWh"
accuracy_decimals: 2
device_class: energy
state_class: total_increasing
value_type: U_DWORD_R
filters:
- multiply: 0.1
- platform: modbus_controller #74 and 75 Total Battery Discharge unsigned 32 bit integer from 2 registers low word first
modbus_controller_id: sunsynk
name: "${friendly_name} Total Battery Discharge (kWh)"
id: sunsynk_total_battery_discharge_kwh
register_type: holding
address: 74
unit_of_measurement: "kWh"
accuracy_decimals: 2
device_class: energy
state_class: total_increasing
value_type: U_DWORD_R
filters:
- multiply: 0.1
- platform: modbus_controller # 78 and 80 Total Grid Import unsigned 32 bit integer from 2 registers low word first????? Using 78 only an unsure how to use 2 diffrent registers!
modbus_controller_id: sunsynk
name: "${friendly_name} Total Grid Import (kWh)"
id: sunsynk_total_grid_import_kwh
register_type: holding
address: 78
unit_of_measurement: "kWh"
accuracy_decimals: 2
device_class: energy
state_class: total_increasing
value_type: U_WORD
filters:
- multiply: 0.1
- platform: modbus_controller # 81 and 82 Total Grid Export unsigned 32 bit integer from 2 registers low word first
modbus_controller_id: sunsynk
name: "${friendly_name} Total Grid Export (kWh)"
id: sunsynk_total_grid_export_kwh
register_type: holding
address: 81
unit_of_measurement: "kWh"
accuracy_decimals: 2
device_class: energy
state_class: total_increasing
value_type: U_DWORD_R
filters:
- multiply: 0.1
- platform: modbus_controller # 85 and 86 Load Power Total unsigned 32 bit integer from 2 registers low word first
modbus_controller_id: sunsynk
name: "${friendly_name} Total Load Power (kWh)"
id: sunsynk_total_load_power_kwh
register_type: holding
address: 85
unit_of_measurement: "kWh"
accuracy_decimals: 2
device_class: energy
state_class: total_increasing
value_type: U_DWORD_R
filters:
- multiply: 0.1
- platform: modbus_controller # 96 and 97 Total PV Power unsigned 32 bit integer from 2 registers low word first
modbus_controller_id: sunsynk
name: "${friendly_name} Total PV Power (kWh)"
id: sunsynk_total_pv_power_kwh
register_type: holding
address: 96
unit_of_measurement: "kWh"
accuracy_decimals: 2
device_class: energy
state_class: total_increasing
value_type: U_DWORD_R
filters:
- multiply: 0.1
################################################ READ SETTINGS ################################################
- platform: modbus_controller # 250 Settings Timezone1
modbus_controller_id: sunsynk
# name: "${friendly_name} Setting Timezone1"
id: sunsynk_setting_timezone1
register_type: holding
skip_updates: ${settings_skipped_updates}
address: 250
filters: #GOOD
- lambda: |-
if (x > 32767) return (x - 65535) /1;
else return (x) /1;
icon: "mdi:clock"
- platform: modbus_controller # 251 Settings Timezone2
modbus_controller_id: sunsynk
# name: "${friendly_name} Setting Timezone2"
id: sunsynk_setting_timezone2
register_type: holding
skip_updates: ${settings_skipped_updates}
address: 251
filters: #GOOD
- lambda: |-
if (x > 32767) return (x - 65535) /1;
else return (x) /1;
icon: "mdi:clock"
- platform: modbus_controller # 252 Settings Timezone3
modbus_controller_id: sunsynk
# name: "${friendly_name} Setting Timezone3"
id: sunsynk_setting_timezone3
register_type: holding
skip_updates: ${settings_skipped_updates}
address: 252
filters: #GOOD
- lambda: |-
if (x > 32767) return (x - 65535) /1;
else return (x) /1;
icon: "mdi:clock"
- platform: modbus_controller # 253 Settings Timezone4
modbus_controller_id: sunsynk
# name: "${friendly_name} Setting Timezone4"
id: sunsynk_setting_timezone4
register_type: holding
skip_updates: ${settings_skipped_updates}
address: 253
icon: "mdi:clock"
- platform: modbus_controller # 254 Settings Timezone5
modbus_controller_id: sunsynk
# name: "${friendly_name} Setting Timezone5"
id: sunsynk_setting_timezone5
register_type: holding
skip_updates: ${settings_skipped_updates}
address: 254
filters: #GOOD
- lambda: |-
if (x > 32767) return (x - 65535) /1;
else return (x) /1;
icon: "mdi:clock"
- platform: modbus_controller # 255 Settings Timezone6
modbus_controller_id: sunsynk
# name: "${friendly_name} Setting Timezone6"
id: sunsynk_setting_timezone6
register_type: holding
skip_updates: ${settings_skipped_updates}
address: 255
filters: #GOOD
- lambda: |-
if (x > 32767) return (x - 65535) /1;
else return (x) /1;
icon: "mdi:clock"
- platform: modbus_controller # 268 Settings SoC Timezone1
modbus_controller_id: sunsynk
name: "${friendly_name} Setting SoC Timezone1"
id: sunsynk_setting_soc_timezone1
register_type: holding
skip_updates: ${settings_skipped_updates}
address: 268
unit_of_measurement: "%"
value_type: U_WORD
icon: "mdi:battery-clock-outline"
- platform: modbus_controller # 269 Settings SoC Timezone2
modbus_controller_id: sunsynk
name: "${friendly_name} Setting SoC Timezone2"
id: sunsynk_setting_soc_timezone2
register_type: holding
skip_updates: ${settings_skipped_updates}
address: 269
unit_of_measurement: "%"
value_type: U_WORD
icon: "mdi:battery-clock-outline"
- platform: modbus_controller # 270 Settings SoC Timezone3
modbus_controller_id: sunsynk
name: "${friendly_name} Setting SoC Timezone3"
id: sunsynk_setting_soc_timezone3
register_type: holding
skip_updates: ${settings_skipped_updates}
address: 270
unit_of_measurement: "%"
value_type: U_WORD
icon: "mdi:battery-clock-outline"
- platform: modbus_controller # 271 Settings SoC Timezone4
modbus_controller_id: sunsynk
name: "${friendly_name} Setting SoC Timezone4"
id: sunsynk_setting_soc_timezone4
register_type: holding
skip_updates: ${settings_skipped_updates}
address: 271
unit_of_measurement: "%"
value_type: U_WORD
icon: "mdi:battery-clock-outline"
- platform: modbus_controller # 272 Settings SoC Timezone5
modbus_controller_id: sunsynk
name: "${friendly_name} Setting SoC Timezone5"
id: sunsynk_setting_soc_timezone5
register_type: holding
skip_updates: ${settings_skipped_updates}
address: 272
unit_of_measurement: "%"
value_type: U_WORD
icon: "mdi:battery-clock-outline"
- platform: modbus_controller # 273 Settings SoC Timezone6
modbus_controller_id: sunsynk
name: "${friendly_name} Setting SoC Timezone6"
id: sunsynk_setting_soc_timezone6
register_type: holding
skip_updates: ${settings_skipped_updates}
address: 273
unit_of_measurement: "%"
value_type: U_WORD
icon: "mdi:battery-clock-outline"
- platform: modbus_controller # 274 Settings Grid Charge Timezone1
modbus_controller_id: sunsynk
# name: "${friendly_name} Setting Grid Charge Timezone1"
id: sunsynk_setting_grid_charge_timezone1
register_type: holding
skip_updates: ${settings_skipped_updates}
address: 274
- platform: modbus_controller # 275 Settings Grid Charge Timezone2
modbus_controller_id: sunsynk
# name: "${friendly_name} Setting Grid Charge Timezone2"
id: sunsynk_setting_grid_charge_timezone2
register_type: holding
skip_updates: ${settings_skipped_updates}
address: 275
- platform: modbus_controller # 276 Settings Grid Charge Timezone3
modbus_controller_id: sunsynk
# name: "${friendly_name} Setting Grid Charge Timezone3"
id: sunsynk_setting_grid_charge_timezone3
register_type: holding
skip_updates: ${settings_skipped_updates}
address: 276
- platform: modbus_controller # 277 Settings Grid Charge Timezone4
modbus_controller_id: sunsynk
# name: "${friendly_name} Setting Grid Charge Timezone4"
id: sunsynk_setting_grid_charge_timezone4
register_type: holding
skip_updates: ${settings_skipped_updates}
address: 277
- platform: modbus_controller # 278 Settings Grid Charge Timezone5
modbus_controller_id: sunsynk
# name: "${friendly_name} Setting Grid Charge Timezone5"
id: sunsynk_setting_grid_charge_timezone5
register_type: holding
skip_updates: ${settings_skipped_updates}
address: 278
- platform: modbus_controller # 279 Settings Grid Charge Timezone6
modbus_controller_id: sunsynk
# name: "${friendly_name} Setting Grid Charge Timezone6"
id: sunsynk_setting_grid_charge_timezone6
register_type: holding
skip_updates: ${settings_skipped_updates}
address: 279
- platform: modbus_controller # 256 # Settings Power Timezone1
modbus_controller_id: sunsynk
name: "${friendly_name} Setting Power Timezone1"
id: sunsynk_setting_power_timezone1
register_type: holding
skip_updates: ${settings_skipped_updates}
address: 256
unit_of_measurement: "W"
value_type: U_WORD
icon: "mdi:flash"
- platform: modbus_controller # 257 # Settings Power Timezone2
modbus_controller_id: sunsynk
name: "${friendly_name} Setting Power Timezone2"